Check our I-MR maths against NIST

Last reviewed 2026-11-03

You can check one of our engine's calculations using a published dataset, rather than taking “tested maths” on trust. This example checks individuals-chart control limits estimated from successive moving ranges.

The reference is section 6.3.2.2 of the NIST e-Handbook. It gives ten successive batch flow readings and the resulting limits. The same data and reference answers are used in SPC Visuals' automated engine tests. Source checked 3 November 2026.

Reproduce the check

  1. Copy these ten readings, keeping their order.
  2. Open the free I-MR calculator and replace its sample in Your readings with the copied values. Leave LSL and USL blank: the source does not supply specification limits.
  3. Select Draw the chart. Compare its centre line, UCL and LCL with the answers below. No account is needed; pasted readings are not stored.
49.6
47.6
49.9
51.3
47.8
51.2
52.6
52.4
53.6
52.1

How the limits are calculated

There are ten readings and nine moving ranges. Each moving range is the absolute difference between adjacent readings; the first is |47.6 − 49.6| = 2.0. Their sum is 16.9.

  • Mean: 508.1 / 10 = 50.81.
  • Average moving range: 16.9 / 9 = 1.877777….
  • Estimated sigma: average moving range divided by 1.128, the d₂ constant for pairs.
  • Individuals limits: mean plus or minus three times that estimated sigma.

Keep full precision until the final rounding. Using the standard deviation of all ten readings estimates variation differently and will not reproduce this moving-range calculation.

Published answers and engine output

Both columns below are rounded to four decimal places, except the mean, which is shown to two. The calculator rounds these results to three decimal places: centre line 50.810, UCL 55.804, LCL 45.816. These are the same answers at its display precision. The average moving range is included here to make the method checkable.

QuantityNISTSPC Visuals
Mean / centre line50.8150.81
Average moving range1.87781.8778
Individuals UCL55.804155.8041
Individuals LCL45.815945.8159

What this check establishes

This is one reproducible arithmetic check of the shared calculation engine, not certification or NIST endorsement. It does not check every chart type, Nelson rule, import format or production configuration.

Ten readings are a small teaching dataset, not a recommended production baseline. Matching these limits does not establish that your process is stable, normally distributed or capable. A real baseline needs enough representative observations and an engineering review of the process and its sampling plan. Control limits describe process variation; specification limits describe what the product must meet.

Run it on your own numbers

Free, no signup, and nothing you paste is stored. Calculator readings are not copied into a workspace.

  • I-MR chart calculator — For processes that give you one number at a time — a batch, an oven, a destructive test. Limits from the mean moving range, run rules evaluated, and an honest note about what an individuals chart cannot see.

Keep a control chart for your line

Import your own CSV or .xlsx readings, review a baseline and lock its limits. Your workspace saves the readings for X̄-R, X̄-S, I-MR and c charts with Nelson-rule signals.

The workspace does not include every free calculator: Gage R&R, Bland–Altman and Levey–Jennings/Westgard remain standalone tools.

Free for 1 characteristic. 1,000 measurements per calendar month. No time limit. No card. Free-plan limits

See it on live data

Read next

  • Common cause and special cause variation — Every process varies. The question is whether the variation is the process being itself or something happening to it — and answering it wrong is how well-meant intervention makes a process worse.
  • What is a Shewhart chart? — Shewhart chart is the proper name for what most people call a control chart. Here is where it came from, why the limits are at three sigma, and which of the family you need.