You can check one of our engine's calculations using a published dataset, rather than taking “tested maths” on trust. This example checks individuals-chart control limits estimated from successive moving ranges.
The reference is section 6.3.2.2 of the NIST e-Handbook. It gives ten successive batch flow readings and the resulting limits. The same data and reference answers are used in SPC Visuals' automated engine tests. Source checked 3 November 2026.
Reproduce the check
- Copy these ten readings, keeping their order.
- Open the free I-MR calculator and replace its sample in Your readings with the copied values. Leave LSL and USL blank: the source does not supply specification limits.
- Select Draw the chart. Compare its centre line, UCL and LCL with the answers below. No account is needed; pasted readings are not stored.
49.6
47.6
49.9
51.3
47.8
51.2
52.6
52.4
53.6
52.1
How the limits are calculated
There are ten readings and nine moving ranges. Each moving range is the
absolute difference between adjacent readings; the first is
|47.6 − 49.6| = 2.0. Their sum is 16.9.
- Mean:
508.1 / 10 = 50.81. - Average moving range:
16.9 / 9 = 1.877777…. - Estimated sigma: average moving range divided by
1.128, the d₂ constant for pairs. - Individuals limits: mean plus or minus three times that estimated sigma.
Keep full precision until the final rounding. Using the standard deviation of all ten readings estimates variation differently and will not reproduce this moving-range calculation.
Published answers and engine output
Both columns below are rounded to four decimal places, except the mean, which is shown to two. The calculator rounds these results to three decimal places: centre line 50.810, UCL 55.804, LCL 45.816. These are the same answers at its display precision. The average moving range is included here to make the method checkable.
| Quantity | NIST | SPC Visuals |
|---|---|---|
| Mean / centre line | 50.81 | 50.81 |
| Average moving range | 1.8778 | 1.8778 |
| Individuals UCL | 55.8041 | 55.8041 |
| Individuals LCL | 45.8159 | 45.8159 |
What this check establishes
This is one reproducible arithmetic check of the shared calculation engine, not certification or NIST endorsement. It does not check every chart type, Nelson rule, import format or production configuration.
Ten readings are a small teaching dataset, not a recommended production baseline. Matching these limits does not establish that your process is stable, normally distributed or capable. A real baseline needs enough representative observations and an engineering review of the process and its sampling plan. Control limits describe process variation; specification limits describe what the product must meet.