GB grid frequency
This is the frequency of the British electricity grid, right now. The target is 50 Hz. Nobody is inspecting it — it just varies. Control limits tell you what normal variation looks like, so when something abnormal happens you know immediately, without staring at the number.
Embed this chart — free, no signup.
GB grid frequency — individuals & moving range
No points to chart yet
This feed is connected but has not collected a full sampling period yet. The chart appears as soon as the first complete points land.
What just happened
Each explanation is fixed text selected by the detected Nelson rule. It describes a pattern to investigate, not a diagnosis of its cause. False alarms are possible.
Why a signal can fire inside the limits
Illustrative example — not this feed's readings. Assume fixed control limits of 7 and 13, with a centre line of 10. These limits are assumed for teaching, not calculated from the six readings below.
Read in time order: 9.7, 9.8, 9.9, 10.1, 10.2, 10.3.
All six readings are inside the limits. Each is higher than the one before it, so Nelson rule 3 first fires at point 6. The headline is Six points in a row rising. An equal reading would break the trend.
The same rule engine checks the live chart above. Its selected rules determine which patterns are flagged; the example does not mean this feed currently has a trend. A signal does not identify a cause or establish that a part is outside specification.
How these charts are built explains the baseline, sampling and rule choices behind the live feeds.
Tick a rule off and its points, its shaded runs and its card below the chart go with it — nothing is refetched, so you are looking at the same readings judged by fewer rules. Change how often a reading is taken and watch the limits move. Sample too often and every reading is almost a copy of the one before it — the chart then thinks the process is far steadier than it is, and draws limits so tight that normal variation looks like a crisis. Only the setting marked (the real one) shows the limits that were locked at baseline and have never been recalculated since.
Data source: Elexon BMRS. BMRS data provided by Elexon under the BMRS Data Licence Terms. SPC Visuals is not affiliated with Elexon BMRS.
Embed or cite this chart
Free to embed. The snippet uses this feed's default sampling and grouping; changes to the controls above are not included. The embed keeps the source credit and a link back to this chart.
Source: Elexon BMRS. BMRS data provided by Elexon under the BMRS Data Licence Terms.
https://www.spcvisuals.com/live/grid-frequency
I-MR control chart of GB grid frequency, drawn from Elexon BMRS. Limits were computed once from the first 96 points and frozen; they are never recalculated from the visible window. How these charts are built →
Open this feed's shop-floor view ↗ — the full-screen display customers hang over a line, on public data. Or see all five feeds as one wall ↗.