From CSV to a locked control chart

Last reviewed 2026-11-09

See what happens to a machining measurement after you import it: choose a study window, lock its limits, inspect a later signal and take the evidence away. You can follow this example in a free workspace. Unlike a free calculator run, this saves the readings in your workspace. Start with an empty workspace to keep the sample separate from production data. The free plan covers 1 characteristic and 1,000 measurements a month; no card is needed.

These are invented teaching readings, not customer data or production results. They represent one diameter, in millimetres, measured every five minutes. One measurement per sampling time makes this an I-MR example. Measurements taken together as rational subgroups need a different chart and sampling plan.

1. Paste the sample and map two columns

In your workspace, open Uploads → Paste spreadsheet readings. Copy the whole block below, including its header. Set Columns separated by to Commas and First row contains column names? to Yes, then select Save and map columns. All timestamps in this example are UTC.

timestamp,diameter_mm
2026-11-08 08:00:00,25.004
2026-11-08 08:05:00,24.998
2026-11-08 08:10:00,25.011
2026-11-08 08:15:00,25.006
2026-11-08 08:20:00,25.001
2026-11-08 08:25:00,24.995
2026-11-08 08:30:00,25.008
2026-11-08 08:35:00,25.002
2026-11-08 08:40:00,24.991
2026-11-08 08:45:00,25.005
2026-11-08 08:50:00,25.010
2026-11-08 08:55:00,24.997
2026-11-08 09:00:00,25.003
2026-11-08 09:05:00,24.994
2026-11-08 09:10:00,25.007
2026-11-08 09:15:00,25.000
2026-11-08 09:20:00,24.996
2026-11-08 09:25:00,25.009
2026-11-08 09:30:00,25.001
2026-11-08 09:35:00,24.999
2026-11-08 09:40:00,25.080

On Column mapping, choose:

  • Characteristic: Create one from this file. Name it Training diameter (mm).
  • Format: Long — one measurement per row. This creates an I-MR characteristic.
  • Timestamp column: timestamp.
  • Value column: diameter_mm. Leave wide-format reading columns unselected; keep decimal separator and date format at auto.

Select Save mapping & parse. Check 21 imported, 0 skipped before continuing. If the counts differ, check the copied header, comma separator and column mapping. Correct the mapping and parse again rather than importing a second copy.

2. Review the first 20 readings, then lock the limits

Open the characteristic's chart from Characteristics, then Preview baseline. Under Change window, enter these inclusive UTC bounds and select Update preview:

  • Window from (UTC): 2026-11-08T08:00:00.
  • Window to (UTC): 2026-11-08T09:35:00.

Check 20 eligible measurements, 0 left out. The 09:40 reading is outside this study window; it stays on the chart. Select Recalculate limits to lock this first baseline. No force override is needed for these 20 readings.

The study mean is 500.037 / 20 = 25.00185. Its 19 successive moving ranges sum to 0.159; divide their average by 1.128 to estimate within-process sigma. The individuals limits are the study mean ± three times that estimate, using full precision before rounding.

QuantityExpected result (mm)
Mean / centre line25.00185
Average moving range0.00836842
Individuals UCL25.02411
Individuals LCL24.97959

The chart uses three decimal places for this imported data: centre line 25.002, UCL 25.024, LCL 24.980. Its Current window mean includes all 21 readings; it is a different quantity from the locked baseline's centre line.

Twenty invented readings teach the controls; they do not establish a suitable production baseline. Review a representative sampling period, measurement system and process conditions before locking real limits. The NIST individuals-chart explanation describes the moving-range method; our separate NIST check reproduces its published data rather than this fictional example.

3. Inspect the later signal without moving the baseline

Select Back to configuration → View chart. The 09:40 value of 25.080 mm exceeds the locked UCL of 25.02411 mm: Nelson rule 1, a point beyond three sigma. With the default rules, it appears under Violations in window and in the Alarm log. Review run opens the signal's review dialog; the inline row also gives the rule, time and extreme value.

The study ends at 09:35, so the later reading does not enter its calculation. Further readings do not move locked limits either. A new baseline requires a deliberate recalculation; do not widen limits just to remove a signal. For a real signal, investigate the process and measurement before recording a cause. The chart identifies a pattern, not its root cause. Acknowledging it records a review; it does not correct the process or erase the signal.

4. Export readings or a period summary

  • On the chart, Download full CSV contains the 21 readings, the control limits in force and recorded rule numbers. Check the 09:40 row for value 25.080, the same baseline limits and rule 1. CSV numbers may omit trailing zeros. Download window CSV restricts the export to the displayed chart points.
  • In Reports → SPC summary, set From and To both to 2026-11-08, then select Generate summary → Download period CSV. This contains one summary row per characteristic, including its period reading count, rather than the individual readings. The training characteristic has 21 readings that day.

We supplied no specification limits, so capability and performance indices are blank. Specifications describe product requirements; control limits describe process variation. A rule-1 signal alone does not say whether a part meets its specification, and an absence of signals does not prove stability or capability.

Once you have checked this path, use your own representative data and sampling plan. Keep the teaching data separate from production records.

Keep a control chart for your line

Import your own CSV or .xlsx readings, review a baseline and lock its limits. Your workspace saves the readings for X̄-R, X̄-S, I-MR and c charts with Nelson-rule signals.

The workspace does not include every free calculator: Gage R&R, Bland–Altman and Levey–Jennings/Westgard remain standalone tools.

Free for 1 characteristic. 1,000 measurements per calendar month. No time limit. No card. Free-plan limits

See it on live data

Read next

  • Cpk vs Ppk — what the gap between them is telling you — Cpk uses within-subgroup sigma, Ppk uses the standard deviation of every reading. When they disagree, the disagreement is the finding — not a rounding artefact to be argued away.
  • Common cause and special cause variation — Every process varies. The question is whether the variation is the process being itself or something happening to it — and answering it wrong is how well-meant intervention makes a process worse.